  model P150E-5 P150E-9 P150E-12 P150E-15 P150E-18 P150E-24 P150E-30 P150E-48 max output wattage[w] 150 150.3 156 150 151.2 156 150 158.4 dc output 5v 30a 9v 16.7a 12v 13a 15v 10a 18v 8.4a 24v 6.5a 30v 5.0a 48v 3.3a specifications model P150E-5 P150E-9 P150E-12 P150E-15 P150E-18 P150E-24 P150E-30 P150E-48 input voltage[v] ac85 - 132 / 170 - 264 1 f ( user-selectable ) or dc220 - 370 current[a] acin 100v * 1 3.2typ ( io=100% ) acin 200v * 1 1.7typ ( io=100% ) frequency[hz] 47 - 440 efficiency[%] 78typ 78typ 80typ 81typ 82typ 82typ 82typ 85typ inrush current[a] acin 100v 15typ ( io=100% ) acin 200v 30typ ( io=100% ) output voltage[v] 5 9 121518243048 current[a] 30 16.7 13 10 8.4 6.5 5.0 3.3 max output wattage[w] 150 150.3 156 150 151.2 156 150 158.4 line regulation[mv] 20max 36max 48max 60max 72max 96max 120max 192max load regulation[mv] 40max 72max 100max 120max 150max 150max 190max 240max ripple[mvp-p] * 2 80max 120max 120max 120max 120max 120max 150max 150max ripple noise[mvp-p] * 2 120max 150max 150max 150max 250max 150max 180max 200max temperature regulation[mv] 0to+50 c 50max 90max 120max 150max 180max 240max 300max 480max output voltage adjustment range[v] t 10% start-up time[ms] 200max ( acin 85v , io=100% ) hold-up time[ms] 15typ ( acin 85v , io=100% ) 25typ ( acin 100v , io=100% ) protection circuit overcurrent protection works over 105% of rating and recovers automatically overvoltage protection works at 115 - 140% of rating isolation input-output ac3 , 000v 1minute , cutoff current = 10ma , dc500v 50m w min ( at room temperature ) input-fg ac2 , 000v 1minute , cutoff current = 10ma , dc500v 50m w min ( at room temperature ) output-fg ac500v 1minute , cutoff current = 100ma , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +65 c , 30 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 30minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , en60950-1 , en50178 , csa c22.2 no.234 complies with den-an and iec60950-1 conducted noise complies with fcc-a * 1 the input current of the agency approved unit is indicated as 3.5a (acin100v) or 1.7a (acin200v). * 2 according to 15mhz oscilloscope or ripple-noise meter(equivalent to keisoku-giken : rm101). * derating is required when operated with case cover. * parallel operation with other model is not possible. P150E unit type p 150 e -5 - o ordering information 1 series name 2 output wattage 3 ul recognized,t u v approved, csa certified:e 4 output voltage 5 optional c :with coating g :low leakage current n :with cover r 12345 p a-78 free datasheet http:///
? derating curve ? overcurrent characteristics ( P150E-5 ) ? rise time & fall time ( P150E-5 ) ? static characteristics ( P150E-5 ) p a-79 P150E external view ?weight : 900g or less (without cover) ?cover is optional ?tolerance : t 1 ?dimensions in mm. ?mounting torque:1.2n . m(12.8kgf . cm)max performance data free datasheet http:///
basic characteristics data * 1 refer to instruction manual. * switching frequency of flyback converter depends on input voltage and load factor. * the value of input current is at acin100v and rated load (as for pt1500u, acin200v and rated load). input fuse 250v 20a 250v 50a 250v 20a 250v 15a 250v 6.3a 250v 5a 250v 3a 250v 3a 250v 2a rated basic characteristics data pt1500u p1500e p600e p300e P150E p100e p50e p30e p15e model forward converter forward converter forward converter 6 29 11 140 150 210 65 - 350 45 - 400 45 - 340 frequency switching circuit method forward converter forward converter forward converter flyback converter flyback converter flyback converter [a] 5.5 3.2 2.2 1.2 0.6 0.3 current input 300 200 200 operation availability * 1 * 1 * 1 * 1 * 1 yes yes yes yes series/parallel parallel operation triac scr scr fr-4 fr-4 fr-4 yes yes yes yes yes yes pcb/pattern thermistor thermistor thermistor triac triac triac inrush protection current fr-4 fr-4 cem-1 cem-1 cem-1 cem-1 material yes yes double sided yes yes yes yes sided single * 1 yes yes yes yes * 1 * 1 series operation yes yes [khz] a-88 p free datasheet http:///


▲Up To Search▲   

 
Price & Availability of P150E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X